Septic system installation in Edmond: sewer first, then DEQ sizing
Before septic system installation in Edmond, for a new house, a replacement, or a sewer question, check the public sewer first, then the state sizing rule. When an on-site system is the path, the work is also septic tank installation. An aerobic septic system is one system the state rules describe. The Oklahoma City roster is aerobic septic system Oklahoma City. What those rules mean by the treatment tank is on aerobic treatment unit Oklahoma.
Edmond Municipal Code section 16.10.010 adopts the International Plumbing Code. Ordinance No. 3961, passed and approved July 10, 2023, amends that section. The city's PDF adopts the Plumbing Code, 2018 Edition, as the city's plumbing code. The amendment says the International Private Sewage Disposal Code which is included as part of the International Plumbing Code is specifically excluded and deleted and not applicable in the City of Edmond. The Building Codes page says that as of August 14, 2023 the city has adopted the 2018 ICC family of codes, and that any permit applied or issued on or after that date falls under the 2018 codes, including the International Plumbing Code 2018. The code library's Chapter 16.10 entry still prints section 16.10.010 as the International Plumbing Code, 2015 Edition (Ordinance 3364, December 10, 2012; Ordinance 3575, December 12, 2016). Ask the City of Edmond Building & Safety which edition applies to the permit. An individual on-site system is sized and installed under OAC 252:641.
Section 16.10.540 adds International Plumbing Code section 701.2.1, Public Sewer Available: a public sewer system shall be considered available to a structure where the structure is located abutting a street, alley or right-of-way in which there is now located a public sewer (Ordinance 3364, December 10, 2012). Ordinance 3961 does not amend section 16.10.540. That sentence defines availability. Whether the pipe in that street, alley, or right-of-way is a public sewer, and whether a septic system can go on that lot, are questions for Building & Safety, 22 E. Main Street, Edmond, OK 73034, (405) 359-4780.
If the building sewer connects to a private sewage disposal system, section 16.10.500, as set by Ordinance 3961, amends International Plumbing Code section 305.4.1: building sewers that connect to private sewage disposal systems shall be a minimum of 12 inches below finished grade at the point of septic tank connection, and building sewers shall be a minimum of 12 inches below grade.
Bedroom count sets the flow. OAC 252:641-1-3(f)(1), amended at 41 Ok Reg, Number 23, effective September 15, 2024, bases the average daily flow for an individual on-site sewage treatment system on 200 gallons per day for a residence of two bedrooms or less, plus 66 gallons per day for each additional bedroom. A three-bedroom residence is 266 gallons per day under that sentence. OAC 252:641-1-3(g) sizes dispersal fields and lagoons from that average daily flow, using the charts in Appendix H, and says the size should be increased if actual or anticipated water use is higher.
OAC 252:641-1-2 defines an aerobic treatment unit as a treatment unit that provides digestion of organic matter through oxidation and has been tested and certified by an ANSI accredited certifier as meeting the most current ANSI/NSF Standard 40, whether or not it includes nitrogen reduction. OAC 252:641-10-2 says an aerobic treatment system is comprised of a trash tank and an aerobic treatment unit, and, when a pressurized dispersal method is used, a pump tank. Effluent from the unit is dispersed as Subchapter 12 describes. The trash tank's minimum liquid capacity is 300 gallons or the average daily flow, whichever is greater, and not less than the capacity used in the NSF/ANSI certification. If the flow on any day during the week exceeds the unit's daily capacity, the system may not be used unless a flow equalization tank meeting OAC 252:641-9 is installed between the trash tank and the unit. OAC 252:641-10-2(g) requires installation to the manufacturer's specifications and maintenance under the most current NSF Standard 40 and Standard 245.
After installation, later city duties for a property inside Edmond are on aerobic septic maintenance in Edmond. The same bedroom-count flow rule applies on a Mustang lot. That metro roster is aerobic septic in Mustang.
Can I put in a septic system inside Edmond city limits?
Section 16.10.010 adopts the International Plumbing Code and says the International Private Sewage Disposal Code is specifically excluded and deleted and not applicable in the City of Edmond. Section 16.10.540 treats a public sewer as available where the structure abuts a street, alley, or right-of-way in which a public sewer is now located. Those sections do not name a required or forbidden system type. Ask the City of Edmond Building & Safety about the lot.
How is a septic system sized in Oklahoma?
OAC 252:641-1-3(f)(1) sets the average daily flow for an individual on-site sewage treatment system at 200 gallons per day for a residence of two bedrooms or less, plus 66 gallons per day for each additional bedroom. OAC 252:641-1-3(g) sizes dispersal fields and lagoons from that average daily flow.
Sources read November 23, 2026: Ordinance No. 3961, the Building Codes page, the indexed Chapter 16.10 text, and OAC 252:641.