Central Oklahoma

Aerobic septic in Yukon.

Canadian County aerobic spray installers on the DEQ list. Confirm coverage before you assume west-metro service.

Start with the company’s roster location, then verify your address.
A Yukon business location does not establish citywide or regional service coverage.

Using the Yukon aerobic septic list

The city page for Oklahoma City is aerobic septic system Oklahoma City.

This page lists Department of Environmental Quality aerobic spray installer records that use Yukon, Oklahoma as the mailing city. 1 listed company is in that set. Homeowners in Yukon and the rest of Central Oklahoma usually need installation, repair, maintenance, pumping, or an inspection — confirm the exact task when you call.

Oklahoma city names on this directory are roster locations, not service-area promises. A company based in Edmond, Norman, Choctaw, Midwest City, or Oklahoma City may or may not drive to Yukon. Ask about your street, system type, and timing before you treat a card as a match.

Statewide, a new aerobic system includes two years of installer maintenance at no extra owner cost. After that, the owner maintains the system or hires help. Local city paperwork can add steps; Edmond is the example we call out because the city publishes a yearly verification note inside city limits.

Most Edmond homes are on City sewer, and the City of Edmond says many others depend on onsite wastewater treatment systems, so aerobic septic maintenance in Edmond is for an aerobic system inside Edmond city limits after you confirm the property is inside them.

One company on this page lists Yukon as its mailing city. For other towns, see aerobic septic in Oklahoma.

Private sewage on a new Yukon subdivision

Ordinance No. 1438 is the Yukon Unified Development Code. The zoning ordinances page lists the file as “ORD 1438 UDC 8-1-23.” The signature page of that PDF says the City Council passed and approved it, and the Mayor signed it, on the 1st day of August, 2023. Development Services says that as of August 5, 2023 the city is working under the new code.

Article 6, Section 604.B applies to the subdivider of a plat inside the corporate limits, not to every existing house. Sanitary sewers are item 3 and start as a connection to the public system. The second numbered line is the exception:

“If a public sanitary sewer system is not reasonably accessible and not within ¼ of a mile as determined by the City Engineer, the subdivider may install a private sewage disposal system. Such private sewage disposal system shall be installed in accordance with the recommendations and requirements of the Oklahoma Department of Environmental Quality and subject to minimum lot size requirements within the City of Yukon.”

The City Engineer decides reasonable access and the quarter-mile distance. That sentence does not print an acreage.

Depth of the building sewer

Ordinance No. 1408 adopts the 2015 International Plumbing Code and puts the plumbing inspector in Development Services. The sewer-depth caption amends Section 305.6.1. The text under it is numbered 305.4.1 and says building sewers that connect to private sewage disposal systems shall be a minimum of 12 inches (305 mm) or as approved by the authority having jurisdiction below finished grade at the point of septic tank connection. Building sewers shall also be a minimum of 12 inches (305 mm) below grade.

Aerobic units under the DEQ rules

The DEQ sewage-treatment page says OAC 252:641 sets design, construction, installation, and operation rules for these systems. From November 1, 2025, DEQ’s page limits anyone without DEQ certification to a single on-site system in a calendar year. OAC 252:641-1-2 defines an aerobic treatment unit as oxidation treatment certified by an ANSI-accredited certifier to the current ANSI/NSF Standard 40, and a certified installer as someone DEQ has certified to inspect and approve that person’s own installations. Subchapter 21 separates Aerobic-Spray and Aerobic-Drip. Self-inspection is limited to that installer’s own work in the certified category.

A new system or a modification needs an Authorization to Construct after DEQ reviews the 581. It may not operate until DEQ, or a certified installer, approves it on Form 641-576, due within 15 days when the installer inspects. OAC 252:641-10-3 is the service rule for the two-year installer duty already noted above, at no additional cost to the owner. The sewage-treatment page lists (405) 702-6100.

Who to ask in Yukon

For a city permit or inspection, Development Services lists plumbing permits and an inspection request. The contact block gives 334 Elm Avenue, Yukon, OK 73099, phone 405-354-6676, and hours Monday through Friday, 8:30 a.m. to 5 p.m. It names Danielle O'Neal as Development Services Director/Planning Director; a note on the same page calls her Assistant Planning Director. Installer certification and the Authorization to Construct go to DEQ at (405) 702-6100.

Questions for a Yukon aerobic service company

Ask the company these questions about your address. This directory does not answer them.

  • On this plat, has the City Engineer found the public sewer not reasonably accessible and not within a quarter mile?
  • Which City of Yukon minimum lot size applies to a private system here?
  • Will the building sewer be at least 12 inches below finished grade at the tank, or is another depth approved?
  • Are you DEQ-certified for Aerobic-Spray, Aerobic-Drip, or both?
  • Has DEQ issued the Authorization to Construct after the 581 review, and who files Form 641-576?
  • What does OAC 252:641-10-3 require the installer to do for two years, and what does the owner do after that?
  • What belongs with Development Services at 334 Elm Avenue, and what belongs with DEQ at (405) 702-6100?
Narrow by job

Tags are a starting point. Confirm the exact job and whether they cover your address.

Start here

36 companies to start with.

1 lists Yukon as the mailing city. 35 list another Central Oklahoma city. That is not a promise they cover every street here. Confirm the address when you call.

Local roster records

1 Yukon mailing-city company

Name, phone, location, and aerobic spray roster status were checked against the DEQ source.

Also in Central Oklahoma

35 other Central Oklahoma mailing cities

These companies list a different mailing city on the Department of Environmental Quality roster. Ask whether they cover your Yukon address.

Sources

Read October 30, 2026.

  • City of Yukon, Ordinance No. 1438, Unified Development Code (PDF). Article 6, Section 604.B.3, item 2, on PDF pages 121–122: the subdivider’s private sewage disposal system when a public sewer is not reasonably accessible and not within a quarter mile, as the City Engineer determines, installed to DEQ requirements and city minimum lot size. Signature page, PDF page 146: passed and approved at a regular City Council meeting and signed by the Mayor on the 1st day of August, 2023. The quarter-mile mark on the scan is the fraction one-quarter.
  • City of Yukon, Zoning Ordinances & PUDs. Lists “ORD 1438 UDC 8-1-23 (PDF).”
  • City of Yukon, Development Services. As of August 5, 2023 the city is working under the new UDC and points readers to Ordinance 1438. Contact block: 334 Elm Avenue, Yukon, OK 73099; phone 405-354-6676; Monday through Friday, 8:30 a.m. to 5 p.m.; Danielle O'Neal as Development Services Director/Planning Director. A note on the same page calls her Assistant Planning Director. The page links plumbing permits and “Request an Inspection.”
  • City of Yukon, Ordinance No. 1408 (PDF). Adopts the International Plumbing Code, 2015 edition, and creates the plumbing inspector inside Development Services. Caption: “Section 305.6.1 Sewer depth is amended to read as follows.” Inserted text numbered 305.4.1: building sewers to a private sewage disposal system shall be a minimum of 12 inches (305 mm) or as approved by the authority having jurisdiction below finished grade at the point of septic tank connection; building sewers shall be a minimum of 12 inches (305 mm) below grade. Labeled an OUBCC amendment.
  • Oklahoma DEQ, On-Site Sewage Treatment. Page says it was last modified April 7, 2026. Chapter 252:641 covers design, construction, installation, and operation. Effective November 1, 2025, individuals not certified through DEQ may install only one on-site sewage treatment system per calendar year. Authorization to Construct after review of the 581. Inspection by DEQ or a certified installer on Form 641-576, due within 15 days when the installer completes it. Local DEQ office and alternative-system questions: (405) 702-6100.
  • OAC 252:641 (PDF). Section 252:641-1-2 definitions of aerobic treatment unit and certified installer. Section 252:641-21-1(g) categories Aerobic-Spray and Aerobic-Drip, and the limit on self-inspection. Section 252:641-10-3: two-year installer maintenance at no additional cost to the owner, then the owner’s duty to maintain the system or hire someone.
  • City of Edmond, Aerobic & Septic System Maintenance, read November 5, 2026. Coffee Creek Water Resources Recovery Facility serves the majority of Edmond’s residents, and many others depend on onsite wastewater treatment systems (OWTS). Used for the Edmond city-limits sentence under “Using the Yukon aerobic septic list.” The wording “most Edmond homes are on City sewer” is the summary already on the Edmond maintenance page linked in that sentence.