Tulsa area

Aerobic septic in the Tulsa area.

No company on this directory lists Tulsa as its mailing city. This page lists Department of Environmental Quality–checked companies whose mailing city is in the Tulsa area. A mailing city is not a coverage promise. Confirm they cover your street.

Start with the company’s roster location, then verify your address.
A Tulsa-area mailing city does not establish citywide or regional service coverage.

Using the Tulsa-area aerobic septic list

The city page for Oklahoma City is aerobic septic system Oklahoma City.

This page lists Department of Environmental Quality aerobic spray installer records that use a Tulsa-area mailing city. 28 listed companies are in that set. Homeowners in Tulsa and the rest of the Tulsa area usually need installation, repair, maintenance, pumping, or an inspection — confirm the exact task when you call.

Oklahoma city names on this directory are roster locations, not service-area promises. A company based in Edmond, Norman, Choctaw, Midwest City, or Oklahoma City may or may not drive to your Tulsa-area street. Ask about your street, system type, and timing before you treat a card as a match.

Statewide, a new aerobic system includes two years of installer maintenance at no extra owner cost. After that, the owner maintains the system or hires help. Local city paperwork can add steps; Edmond is the example we call out because the city publishes a yearly verification note inside city limits.

Inside Tulsa city limits: the 250-foot sewer rule

Tulsa Metropolitan Area Planning Commission staff report MR-25 (hearing August 20, 2025) includes a July 14, 2025 letter from Tanner Consulting, LLC to the City of Tulsa Planning Office. That letter quotes Tulsa Revised Ordinances Title 17 Section 906(A):

“It shall be unlawful for any person to install, maintain, operate or use any septic tank system within the boundaries of any sewer district or where such system is upon any premises which abut upon any public district or public lateral sewer line, or which is within two hundred fifty (250) feet of such line.”

In plain words: if the lot is inside a sewer district, abuts a public sewer line, or is within 250 feet of one, the quoted section makes it unlawful to install, maintain, operate, or use a septic tank system. The same letter says a site more than 250 feet from a public sanitary sewer line is not subject to Section 906(A), and septic tank systems may be used in accordance with Oklahoma Department of Environmental Quality standards, as set forth by section 5-130.1.D of the subdivision regulations. The letter is about one tract, the northeast corner of East 11th Street South and South 161st East Avenue. Confirm the sewer distance for your address with the City of Tulsa before you plan a new aerobic system. This page does not describe enforcement or fees.

DEQ steps for a new or changed aerobic system

A new or modified aerobic system still follows the Department of Environmental Quality on-site sewage steps. Those steps are separate from the Tulsa sewer-distance question above. The steps below are from the DEQ On-Site Sewage Treatment page, read October 23, 2026. What an aerobic treatment unit is sits on what an aerobic treatment unit is. This page does not repeat that guide.

The 581. The Report for On-Site Sewage, commonly called the 581, determines what types of on-site systems are allowed for the property. A soil profile digs a minimum of three holes or pits in the dispersal area. Those results are used to determine all allowable system types, including aerobic with spray or drip irrigation. Soil profile tests may only be conducted by DEQ or a DEQ-certified soil profiler.

Authorization to Construct. Before installing a new system or modifying an existing one, an Authorization to Construct must be purchased and issued by DEQ. DEQ reviews the 581 before it issues that authorization.

Inspection. A new installation or a modification must be inspected and approved by DEQ, or installed, self-inspected, and approved by a certified installer, before the system may be placed into operation. The final inspection is documented on DEQ Form 641-576. A certified installer must submit that form to DEQ within 15 days of completion.

The same page says: “Effective November 1, 2025, individuals not certified through DEQ may only install one (1) on-site sewage treatment system per calendar year.”

Why a Tulsa-area lot ends up with an aerobic septic system

A mailing city on a company card does not describe the soil under a Tulsa-area address. Oklahoma State University Extension PSS-2275, Aerobic Treatment System (publication line 0714), says conventional systems that rely on the soil are preferred where the soil is deep and medium textured. The fact sheet says further treatment, before the wastewater reaches the soil, is required where the texture is too clayey or too sandy, or where the soil is too shallow to an impervious layer or a water-saturated layer. An aerobic treatment unit is the system that fact sheet describes for those limits. A Tulsa-area lot ends up with an aerobic septic system when the soil test for that lot finds them.

Web Soil Survey, operated by the USDA Natural Resources Conservation Service, is the public soil map for that first look. The survey home page and the Oklahoma NRCS soils page call it the single authoritative source of soil survey information from the National Cooperative Soil Survey. For an area of interest it can produce a soil map, soil descriptions, and suitability ratings. The NRCS guide to Web Soil Survey 3.0 says a user can open that area by street address, by state and county, or by latitude and longitude. The Soil Data Explorer guide lists Septic Tank Absorption Fields as a sanitary-facility interpretation. The home page says soil surveys are for general farm, local, and wider area planning, and that an onsite investigation is needed in some cases, including certain engineering applications. A map rating is not the Report for On-Site Sewage for one address.

The soil profile is the onsite test DEQ uses. The DEQ on-site sewage page says a soil profile test may be conducted only by DEQ or a DEQ-certified soil profiler. OAC 252:641-1-2 defines a certified soil profiler as a person DEQ has certified to perform soil profile descriptions used to design on-site systems. OAC 252:641-3-1(b) says an individual performing soil profiles must be certified by DEQ, and that a soil test may be performed only by a professional engineer, professional land surveyor, professional sanitarian, or professional environmental specialist registered in Oklahoma, by a soil scientist as defined in 27A O.S. Section 3-1-103(20), or by a DEQ environmental program specialist. When a soil test is required, the results go to the local DEQ office on DEQ Form 641-581, or in a format DEQ approves. OAC 252:641-3-1(a) requires the test for a new field and for a modification, except a lagoon and except aerobic spray sized for Group 5 soil in the matching net evaporation zone. The DEQ page also describes a design-only path, always based on Group 5 soil, which it calls the highest clay content, and limits that path to aerobic spray or a lagoon. OAC 252:641-3-2 limits a percolation test, including a pre-existing test, to a conventional subsurface absorption field.

PSS-2275 says a National Sanitation Foundation Standard 40 aerobic treatment system is for residential sewage and cannot be used when average daily flow is less than 100 gallons per day or greater than 1,500 gallons per day. The aeration tank must meet the most current ANSI/NSF Standard 40. OAC 252:641-10-1, as amended effective September 15, 2024, sets those same flow limits and bars the system when biochemical oxygen demand is greater than 2.5 pounds per day. Designs outside those limits have to be permitted as alternative systems. OAC 252:641-10-2 requires the unit to be tested and certified by an ANSI-accredited third-party certifier to the most current NSF/ANSI Standard 40. PSS-2275 states a minimum lot of three-quarters of an acre with a private well on the lot, and one-half acre on a public water system. PSS-2275 says spray effluent is disinfected and subsurface drip effluent is not. The DEQ Residential Aerobic Treatment Systems fact sheet (March 2025) says spray disinfection is required, typically chlorine in liquid or tablet form, and that treated water goes to a spray field or a pressurized drip line. Tank parts are on the aerobic treatment unit guide.

Before septic system installation, and before septic tank installation, ask three things.

  • Ask whether the Report for On-Site Sewage, the 581, is already on file for the address. The DEQ steps higher on this page are the published path for that report.
  • Ask for the installer number and check it on the DEQ certified installer list. The columns include installer number, business name, business city, business phone, aerobic spray, and aerobic drip. Read the spray cell and the drip cell as separate answers.
  • Ask what the two-year installer maintenance covers. PSS-2275 says the installer maintains the system for two years after installation at no cost to the owner: repair, adjust, or replace broken or malfunctioning parts; record trash-tank sludge depth and aeration-tank sludge volume at least every six months; and write the owner about repairs, measurements, and any need to pump the sludge. The March 2025 DEQ fact sheet says that cost is included in the installation, says to call the installer during those two years, and says to call DEQ at 1-800-522-0206 if the maintenance is not provided. After two years the owner does the maintenance or hires a maintenance provider.

The Mustang mailing-city roster is aerobic septic in Mustang. The Oklahoma City roster is aerobic septic system Oklahoma City.

Narrow by job

Tags are a starting point. Confirm the exact job and whether they cover your address.

Start here

28 companies to start with.

3 list Broken Arrow as the mailing city. 25 list another Tulsa area city. That is not a promise they cover every street here. Confirm the address when you call.

Local roster records

3 Broken Arrow mailing-city companies

Name, phone, location, and aerobic spray roster status were checked against the DEQ source.

Also in Tulsa area

25 other Tulsa area mailing cities

These companies list a different mailing city on the Department of Environmental Quality roster. Ask whether they cover your Tulsa-area address.

Sources

  • Tulsa Metropolitan Area Planning Commission staff report MR-25 (City of Tulsa Planning Office, hearing August 20, 2025), read October 23, 2026. The Title 17 Section 906(A) quotation and the more-than-250-feet sentence are in the attached July 14, 2025 letter from Tanner Consulting, LLC, about the tract at the northeast corner of East 11th Street South and South 161st East Avenue. The letter quotes: it is unlawful to install, maintain, operate, or use a septic tank system inside a sewer district, on premises that abut a public district or public lateral sewer line, or within 250 feet of that line. It then says that site, more than 250 feet from a public sanitary sewer line, is not subject to Section 906(A), and septic tank systems may be used in accordance with Oklahoma Department of Environmental Quality standards, as set forth by section 5-130.1.D of the subdivision regulations. The Tulsa code library at library.municode.com/ok/tulsa blocked this fetch, so this page cites the ordinance only as that exhibit quotes it.
  • Oklahoma DEQ, On-Site Sewage Treatment, read October 23, 2026. The 581 report sets allowed system types. A soil profile uses a minimum of three holes or pits; soil profile tests may only be conducted by DEQ or DEQ-certified soil profilers (the live page spells the word “Ceritified”). Results can allow aerobic with spray or drip irrigation. An Authorization to Construct must be purchased and issued by DEQ before a new system or a modification, and DEQ reviews the 581 first. Final inspection is on DEQ Form 641-576, by DEQ or a certified installer, and a certified installer submits that form within 15 days. “Effective November 1, 2025, individuals not certified through DEQ may only install one (1) on-site sewage treatment system per calendar year.”
  • This directory’s companies hub, recounted November 19, 2026: 134 cards, 28 in the Tulsa region, 36 in central Oklahoma, and 68 in the rest of the state. Two more cards list a mailing city outside Oklahoma (Howe, Texas and Greenwood, Arkansas). The “28 companies to start with” heading on this page matches that recount. Company-card phones were not changed.
  • Oklahoma State University Extension PSS-2275, Aerobic Treatment System, publication line 0714, read November 20, 2026. Conventional systems are preferred in deep, medium-textured soil. Further treatment is required where soil is too clayey, too sandy, or too shallow to an impervious or water-saturated layer. An NSF Standard 40 system is for residential sewage between 100 and 1,500 gallons per day. The aeration tank meets the most current ANSI/NSF Standard 40. Lot size on the sheet is at least three-quarters of an acre with a private well on the lot, or one-half acre on a public water system. Spray is disinfected. Subsurface drip is not. The installer maintains the system for two years after installation at no cost to the owner and, in that period, repairs parts, records trash-tank sludge depth and aeration-tank sludge volume at least every six months, and writes to the owner about repairs, measurements, and pumping. The print PDF at extension.okstate.edu returned a challenge page on this read, so the quotations are from the pods.okstate.edu PDF of the same fact sheet number.
  • USDA NRCS Web Soil Survey, read November 20, 2026, and the Oklahoma NRCS soils page. Web Soil Survey is the authoritative soil-survey source. It supports general planning. An onsite investigation is needed in some cases, including certain engineering applications. Navigation by street address, state and county, or latitude and longitude is in the Web Soil Survey 3.0 guide. Septic Tank Absorption Fields is listed in the Soil Data Explorer guide. No Tulsa-area map unit is named here.
  • OAC 252:641, PDF last-modified August 15, 2025, read November 20, 2026. Certified soil profiler in 252:641-1-2. Soil-test requirement, Group 5 spray exception, and who may perform a soil profile in 252:641-3-1. Percolation tests limited to conventional subsurface absorption fields in 252:641-3-2. Flow limits and the 2.5-pound biochemical oxygen demand limit in 252:641-10-1, amended effective September 15, 2024. NSF/ANSI Standard 40 certification of the aerobic treatment unit in 252:641-10-2.
  • DEQ, Residential Aerobic Treatment Systems, fact sheet dated March 2025, read November 20, 2026. Spray disinfection, typically chlorine. Dispersal to a spray field or a pressurized drip line. Two-year maintenance included in the installation cost. Call 1-800-522-0206 if the installer does not provide it. After two years the owner maintains the system or contracts with a maintenance provider.
  • DEQ certified installer list, read November 20, 2026. Columns include installer number, business name, business city, business phone, aerobic spray, and aerobic drip.